TSOP01.B - Alma Platinum Ice Soprano - Settings

Settings for the Alma Soprano Ice Platinum, approved by the Doctor. Source: settings sheet of 26 Sep 2026 (PDF).

Fluence columns I to VI are the client's skin type, decided by the Doctor.

Sr Mode Body area Grid (cm²) Energy (kJ) I II III IV V VI
1 SHR Arms 100 - 200 8 3 4 5 6 7 8
2 SHR Legs 100 - 200 16 3 4 5 6 7 8
3 SHR Back 200 - 300 24 3 4 5 6 7 8
4 SHR Bikini 50 - 100 4 3 4 5 4 5 VERIFY: "?" in the PDF
5 SHR Face 50 - 100 4 3 4 5 5 6 6
6 HR Upper lips na 16 - 18 na na na na na na
7 HR Chin na 16 - 18 na na na na na na
8 HR Side locks na 16 - 18 na na na na na na
9 HR Forehead na 16 - 17 na na na na na na
10 Stack Ear lobes 25 2 2 2 2 3 3 4
11 Stack Forehead 25 2 2 2 2 3 3 4
12 Stack Lips corners 25 2 2 2 2 3 3 4
13 Stack Bikini 50 4 2 2 2 3 3 4
Before the test shot

Check that the machine screen shows these values and the diary energy of the last session.

How to read


  • Mode, by area:
    • HR (Hair Removal): a single pulse at each treatment spot.
    • SHR (Super Hair Removal): multiple pulses while moving the handpiece over the treatment area.
    • Stack: multiple pulses at the same treatment spot.
  • Grid, by treatment area: the size of one grid square in cm².
  • Energy, by session: where two numbers are given, they are the range. Start at the first number and go up to the second in later sessions.
  • Fluence, by skin type: start with the lowest recommended value for the client's skin type. Increase gradually in later sessions, based on comfort and treatment response.